KM is the main contactor. KS makes the wye point; KD connects the windings in delta. KS and KD must never be in together: they’re interlocked electrically and usually mechanically too.
A big motor started straight on the line takes six to eight times its running current and dips the whole board. Compare the ways round that, hunt down the usual wye-delta faults, and set a purifier’s overload bypass so it starts without cooking the motor.
KM is the main contactor. KS makes the wye point; KD connects the windings in delta. KS and KD must never be in together: they’re interlocked electrically and usually mechanically too.
The motor drives the bowl through a friction clutch: pads thrown out against a drum. The motor comes up to speed in seconds, but the heavy bowl takes minutes, and all that time the motor pulls well over its full-load current.
A thermal overload set to the motor’s FLA would trip partway through every start. So the starter bypasses the overload (or shorts its current transformer) for a set time, then hands protection back.
Set the timer from a stopwatch on a good start plus a margin, not wound up to the maximum. Every minute of bypass is a minute the motor has no overload protection; if the bowl’s jammed or the brake is on, that’s a minute of locked-up current in the windings.
A start that takes longer than it used to means slipping pads (worn or oily). Too short a start with high current means too many pads. Some installations use a class 30 heavy-start overload instead of a bypass; the idea is the same.