ETO · Part 4 · Motors, starters and drives

Electro-Hydraulic Deck Crane

Deck crane CR1, 25 t, as in the Deck Cranes lesson. One electric motor drives the hydraulic pump. A PLC switches the valve coils for hoist, luff and slew. Limits, the SWL limiter and the E-stops come in as PLC inputs. Everything crosses the slip rings in the pedestal. Take a fault, read the diagnostic page, walk the meter, fix it and prove it.

The pump motor starts wye-delta. Power is 440 V 60 Hz from P-16 on the main board. Control is 24 V DC. For an all-electric hoist (its own motor, contactors and brake) use the Crane Control simulator.

Work order

Pick Give me a fault for a broken crane and a work order. Free run is a healthy crane to learn on first.

Hands
Main board
Crane house
Cab
Pedestal
Joystick
On the hook

Swipe the picture sideways to see all of it.

Tap any part for what it is, a look at it, and the jobs you can do on it. Seen from above, slewing to starboard is clockwise. Time runs fast: an overload that takes minutes on deck takes seconds here.

How to use it
  1. Start with Free run. Press START and watch the pump motor go wye, then delta. Move the joystick. Look at the diagnostic page and the PLC lights.
  2. Meter: pick V and tap test points on the drawing. Black starts parked on 0 V. The lead with the gold edge is the one that moves next; tap a lead to pick it. On the 440 V sheet, tap two points.
  3. Ω only works on a dead circuit. For the crane house, lock Q1. For the slip rings and JB-C12, lock P-16 at the main board: they are upstream of Q1. With a valve plug off, you can read the coil alone.
  4. A is the clamp: tap a dashed ring.
  5. While you hold START in, the PLC keeps trying to start, so you can measure.
  6. When you know what is wrong: lock it off, prove it dead with the meter, then tap the part and pick the job. Then put the crane back in service, prove it, and hand it back.
—

Tap a test point on the drawing.