Everything in series. Both emergency stops, then the joystick, then the limit switch for that direction, then the overload limiter (lifting only), then the other direction’s contactor interlock, then the coil. Any one open and that motion stops.
Limits stop one direction only. The upper hoist limit stops hoisting but still lets you lower out of it. A crane that won’t go one way but goes the other points straight at that direction’s limit or contactor.
The brake is spring-applied and electrically released. No power, brake on: that’s the safe failure. If the brake doesn’t release, the motor drives against it, hums and trips. If the brake doesn’t hold, the load creeps when you let go of the joystick.
Never bypass a limit or the overload limiter to get the job done. Find out why it opened.