One lead of each diode is lifted from the exciter winding. Pick a diode, then test it both ways with the meter on diode test.
PMG (permanent magnet generator): magnets on the shaft, coils on the frame. It makes power for the AVR from the moment the shaft turns, whatever the main output is doing.
AVR: compares the output voltage (through the sensing transformer) with its setting and feeds DC to the exciter field.
Exciter: an upside-down generator. Its field is stationary; its armature turns with the shaft and makes three-phase AC.
Rotating rectifier: six diodes on the shaft turn that AC into DC for the main field. A varistor across them soaks up voltage spikes.
Main field and stator: the spinning DC field induces 440 V in the main stator. A couple of amps in the exciter field control hundreds of amps in the main field: about a hundredfold from one end of the chain to the other.
Self-excited sets without a PMG take AVR power from their own output, so they rely on residual magnetism to start building up. Lose that and they need their field flashed.
Good diode: roughly 0.4 to 0.7 V one way, OL the other. Shorted: near zero both ways. Open: OL both ways. Test them all: they’re cheap, and a set that lost one often has another on the way.